Detalhes da Ordem de Serviço 111224

Visualize todas as informações, fotos, arquivos e dados técnicos da OS 111224 de forma organizada.

Informações do Cliente

Nome: 1-Teste

E-mail: pablo.zanata@gmail.com

CNPJ: 12.345.678/9101-11

Dados da OS

Em dia

OS: 111224

NF Rem Conserto: 455

NF JPL: 879

NF Devolução: 541

Data: 01/07/2025

Garantia até: 01/01/2026

Tipo de Manutenção: Limpeza

Tipo de Falha: Elétrica

Tipo de Defeito: Baixa isolação

Observação: Lorem Ipsum is simply dummy text of the printing and typesetting industry. Lorem Ipsum has been the industry's standard dummy text ever since the 1500s, when an unknown printer took a galley of type and scrambled it to make a type specimen book. It has survived not only five centuries, but also the leap into electronic typesetting, remaining essentially unchanged. It was popularised in the 1960s with the release of Letraset sheets containing Lorem Ipsum passages, and more recently with desktop publishing software like Aldus PageMaker including versions of Lorem Ipsum.

Motor: 222-Teste 2

Marca: Weg

Tipo de Equipamento: Redutor

Potência: 1215

RPM: 10000

Tensão: 220 – 3 pontas

Corrente em Trabalho: 98652

Corrente Máxima Permitida: 51186

Rolamento LA: 31566

Rolamento LOA: 8919848

Temperatura Máxima Permitida: 1516189

Tipo de Lubrificação: Não se aplica

Tipo de Tampa: Normal

Acessórios: Nenhum

Fotos

Informação de Dados de Testes

Tensão do Teste: 440

Corrente em Vazio: 4150

Temperatura: 123132

Vibração: 1321231

Dados de Instalação

Setor: Setor I

Máquina: 002-Máquina Teste 2

Responsável Instalação: Pablo Zanata

Observação Instalação: Teste de inserção de dados de instalação pelo usuário.

Data Instalação: 25/05/2026

Próxima Manutenção: 01/07/2026

Número do Patrimônio: 312412312542312

Fotos

Anexos

Análise de vibração:

Download (Analise-de-vibracao.pdf)